EBMM马达R3G400

EBMM马达R3G400

Nominaldata
Type R3G400-RP45-61 Motor M3G084-FA
Phase 1~ Nominal voltage VAC 230 Nominal voltage range VAC 200 .. 277 Frequency Hz 50/60
Type of data definition ml Speed min-1 1300 Power input W 330 Current draw A 1.5 Min. ambient temperature °C -25 Max. ambient temperature °C 40
ml = max. load · me = max. efficiency · fa = running at free air · cs = customer specs · cu = customer unit Subject to alterations
DataaccordingtoErPdirective
Installation category A Efficiency category Static Variable speed drive Yes Specific ratio* 1.00 * Specific ratio = 1 + pfs / 100 000 Pa
Actual Request 2013 Request 2015 Overall efficiency ηes 64.3 42.3 46.3 Efficiency grade N 80 58 62 Power input Ped kW 0.32 Air flow qv m³/h 2805 Pressure increase pfs Pa 242 Speed n min-1 1270

R3G400-RP45-61
Technicalfeatures
Mass 6.4 kg Size 400 mm Surfaceofrotor Coated in black Materialofelectronicshousing Die-cast aluminium Materialofimpeller PP plastic Numberofblades 6 Directionofrotation Clockwise, seen on rotor Typeofprotection IP 20 Insulationclass "B" Humidityclass F0 Max.permissibleambientmotor temp.(transp./storage) +80 °C Min.permissibleambientmotor temp.(transp./storage) -40 °C Mountingposition Shaft horizontal or rotor on top; rotor on bottom on request Condensatedischargeholes None Operationmode S1 Motorbearing Ball bearing Technicalfeatures - Operation and alarm display: reversible voltage output 0 V / +15 V - Integrated PID controller - Motor current limit - PFC, active - RS485 ebmBUS - Soft start - Control interface with SELV potential safely disconnected from the mains - Over-temperature protected electronics / motor - Line undervoltage / phase failure detection EMCinterferenceimmunity Acc. to EN 61000-6-2 (industrial environment) EMCharmonics Acc. to EN 61000-3-2/3 EMCinterferenceemission Acc. to EN 61000-6-4 (industrial environment) Touchcurrentacc.IEC60990 (measuringnetworkFig.4,TN system) <= 3.5 mA Electricalleads With plug Motorprotection Thermal overload protector (TOP) wired internally Protectionclass I (if protective earth is connected by customer) Productconformingtostandard EN 61800-5-1; CE Approval UL 2111; GOST; CSA C22.2 Nr.77

Charts:Airflow50Hz
pfs @ rho=1,2 kg/m³
qv [m³/h] 4.0003.5003.0002.5002.0001.5001.0005000
qv [CFM] 2.4002.2002.0001.8001.6001.4001.2001.0008006004002000
pfs [Pa]
400
380
360
340
320
300
280
260
240
220
200
180
160
140
120
100
80
60
40
20
0
pfs [InH2O]
1,6
1,5
1,4
1,3
1,2
1,1
1
0,9
0,8
0,7
0,6
0,5
0,4
0,3
0,2
0,1
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Measurement: LU-142789
Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed.
Measured values
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
U V 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230
f Hz 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
n min-1 1300 1300 1300 1300 1100 1100 1100 1100 900 900 900 900 700 700 700 700
Ped W 267 313 330 308 158 199 217 192 87 109 119 105 41 51 56 50
I A 1.16 1.37 1.50 1.35 0.69 0.87 0.95 0.84 0.38 0.48 0.52 0.46 0.18 0.22 0.25 0.22
LpAin dB(A) 72 67 59 58 67 63 55 54 62 58 50 49 56 52 44 43
LwAin dB(A) 78 73 66 67 74 69 63 63 69 64 58 58 62 58 51 51
qv m3/h 4130 3470 2575 1695 3465 2985 2245 1450 2835 2445 1835 1185 2205 1900 1425 925
pfs Pa 0 140 260 340 0 104 197 249 0 69 132 167 0 42 80 101 U = Supply voltage · f = Frequency · n = Speed · Ped = Power input · I = Current draw · LpAin = Sound pressure level inlet side · LwAin = Sound power level inlet side · qv = Air flow pfs = Pressure increase